ThermaTechSpace thermal management

Engineering cases

Completed engineering work described by operating case, heat path and deliverables. Detailed flight figures are confidential by contract.

Commercial satellite thermal design

CASE
Whole-satellite thermal control for LEO commercial satellites. Orbital heat flux, eclipses and unit heat loads jointly constrain radiator area and conduction paths.
HEAT PATH
Define the radiator and primary heat path first, then couple high-power units to the structure or a heat-pipe network; verify both eclipse and full-sun cases with transient analysis.
DELIVERABLES
Thermal architecture, transient analysis results, thermal-control implementation plan. Detailed figures are confidential by contract.

6U board thermal design

CASE
A high-heat-flux 6U board. The package and connectors rule out any cooling path other than conduction.
HEAT PATH
Conduction and spreading first: thermal interface materials, a vapor-chamber or cold-plate path, and interface thermal resistance into the structure.
DELIVERABLES
Board-level heat-path scheme and analysis. Detailed figures are confidential by contract.

UAV module thermal design

CASE
A UAV module constrained simultaneously by aerodynamic shape, weight and the cabin mounting surface.
HEAT PATH
Lay out conduction paths within the permitted mounting surface to keep local hot spots out of neighboring avionics.
DELIVERABLES
Module cooling scheme. Detailed figures are confidential by contract.

Phase-change device design

CASE
Peak heat load briefly far exceeds average heat-rejection capacity. The answer is buffering, not sizing the radiator for the peak.
HEAT PATH
A phase-change device absorbs the peak while steady-state heat continues through the radiation/conduction main path.
DELIVERABLES
Phase-change device scheme and operating-case description. Detailed figures are confidential by contract.

Upper-stage thermal analysis

CASE
An upper stage has a short flight profile and fast-changing heat flux; steady-state ground assumptions do not hold.
HEAT PATH
Transient thermal analysis and verification along the flight timeline, not a single equilibrium temperature.
DELIVERABLES
Flight-profile thermal analysis report. Detailed figures are confidential by contract.